802.11n - 40MHz - Mod and Power
C Measurement Library

WLAN_Meas_Lib_C_Ex11 - 802-11n - 40MHz - Mod and Power.zip

This example demonstrates the use of the WLAN Measurement Library
DLL interface in Microsoft Visual C++ V6.0 to perform measurements
on a 802.11n 40MHz bandwidth signal:

  • Assign digitizer by resource strings
  • Set measurement parameters
  • Enable required measurements
  • Power Profile
      Average Power
      Peak Power
      Burst Length
      Rising Edge Time
      Falling Edge Time
    Modulation Accuracy
      System Type
      Modulation Type
      Data Rate
      HT Format
      HT MCS
      EVM RMS
      EVM Data Carriers
      EVM Pilot Carriers
      RCE RMS
      RCE Data Carriers
      RCE Pilot Carriers
      Frequency Error
      Symbol Clock Error
      Carrier Leak
      IQ Gain Imbalance
      IQ Skew
      Number of PSDU Bits
      Number of PSDU Symbols
    Spectral Flatness
      Overall
      Upper
      Lower
  • Make measurements
  • Retrieve measurement results

A DUT or signal generator will need to be generating
802.11n (40MHz bandwidth) RF bursts as follows:-
RF Frequency....: 2000MHz

It assumes that the following has been installed successfully:

Hardware:
=========
Aeroflex 3011 RF Synthesizer PXI module
Aeroflex 303xC RF Digitizer PXI module

Software:
=========
Aeroflex PXI Module Software - V6.9.0 or better
Aeroflex WLAN Measurement Suite - V2.0.0 or better

It is also assumed that:

The 3010 LO output is connected to the 3030 LO input
The 303x IF output is connected to the 303x IF input (if applicable)

 


Disclaimer of Warranty

This example code is provided 'as is' without warranty.

Neither Aeroflex nor the author(s) warrant that the functions of the software will meet your requirements or that the media is compatible with any computer system on which it is used or that operation of the software will be unlimited or error free. You assume responsibility for selecting the software to achieve your intended results and for the installation of, the use of and the results obtained from the software. In no event shall Aeroflex or its suppliers be liable for any damages whatsoever arising out of installation of the software or incompatibility with any computer system or technical limitation of the software or use or inability to use the software, even if advised of the possibility of such damages. Neither Aeroflex nor the author(s) will be liable for any loss or damage of any nature suffered by any party as a result of reliance upon or reproduction of or any errors in any contents of the software.