Powerful capabilities for avionics maintenance

The DATATRAC 600 is a combination ARINC 429/629 data bus analyzer with dual, independent ports for each bus standard. Nearly identical functions are provided for each bus type. These include basic receive and transmit functions along with a general record mode and a powerful breakpoint mode. The standard RS-232 port is used for downloading real time or recorded data and for uploading new label/word definitions. The standard DAC port can be used to provide a trigger pulse or to drive recorders or instruments. An optional GPIB port permits remote control of all functions. PC software is available to aid the user in defining their own data definition table(s). The large graphical display and integrated keyboard provide an informative and intuitive user interface.

Features

  • Two ARINC TX/RX ports and two ARINC 629 transceiver ports
  • Operates six to eight hours on the internal battery or power from external 28 VDC or 105-250 VAC
  • Easy menu-driven setup allows intuitive control of unit
  • Multi-window display of data in ENGINEERING (B777 default for 629), HEX, BINARY, USER DEFINED, and GRAPHICAL formats.
  • Powerful record and fault analyzer modes
  • Williamsburg protocol software extension available for ARINC 429 file transfer functions
  • RS-232C and DAC interface ports standard, and GPIB optional
  • Software available for RS-232 port (Download/Upload and Word definitions)


ARINC 629 Receiver Operation

  • Ports: 2
  • Bus Frequency: 2 MHz
  • Input Electrical Characteristics: Doublet as specified for SIM input in the Boeing D227W201 Universal Data Sheet
  • Word Update: 1 ms to 10 sec, update rate displayed as instantaneous, min or max value
  • Display Format: Prestored engineering units, hex, binary, user, ASCII, and graphic plots
  • Wordstrings Receivable: 4096
  • Words Selectable: 255 words per wordstring, 32 wordstrings
  • Bus Activity Monitor: Monitors loss of individual words; monitor sensitivity selectable
  • Real-time Download/Conversion RS-232C or 12-bit DAC port

ARINC 629 Transmitter Operation

  • Ports: 1 standard, 2nd optional
  • Bus Frequency: 2 MHz
  • Output Electrical Characteristics: Doublet as specified for SIM output in the Boeing D227W201 Universal Data Sheet
  • Transmit Interval: 0.5 to 64 ms (selectable)
  • Display Format: Prestored engineering units, hex, binary, user, ASCII, and graphic plots
  • Terminal Gap: 1 to 128 µS (selectable)
  • Synchronization: C Mode communication provisions with external terminals
  • Display Format: Prestored engineering units, hex, binary, user, and ASCII
  • Maximum Words per Wordstring: 256
  • Maximum Wordstrings: 31 x 31
  • Dynamic Transmit Repeat pattern of ramps and flat segments. Levels programmable between ± full scale and segment times of 0 to 999.999 sec

ARINC 629 Breakpoint Operation

  • Label Sequence: A, B, A or B, A then B
  • Data Conditions: EQ, NEQ, OR, GT, LT, /GT/, /LT/
  • Event Count: 1 to 99 before break
  • History: Up to 40,960 words in a programmable window about the breakpoint; optional time stamp
  • Trigger Pulse: 5V, 20 µs

ARINC 629 Record Operation

  • Channels: Up to 32 data words from any combination of receive ports
  • Sample Interval: 1 ms to 10 sec (selectable)
  • Record Capacity: 120 Kbytes
  • Playback Options: Graphic plots, data lists, DAC download, RS-232C download

ARINC 429 Receiver Operation

  • Ports: 2
  • Bus Frequency: 12-14.5 kHz or 100 kHz (selectable)
  • Input Levels: ± 6.5 VDC to ± 13.5 VDC (A to B)
  • Input Impedance: 12.0 Kohms
  • Word Update: 1 ms to 10 sec, update rate displayed as instantaneous, min or max value
  • Display Format: Prestored engineering units, full or data field hex and binary, user, ASCII, and graphic plots
  • Maximum Words: 256 per SDI per channel
  • Bus Activity Monitor: Monitors loss of individual words; monitor sensitivity selectable
  • Real-time Download/Conversion RS-232C or 12-bit DAC port

ARINC 429 Transmitter Operation

  • Ports: 2
  • Bus Frequency: 12.0 kHz, 12.5 kHz, 14.5 kHz, or 100 kHz (selectable)
  • Output Levels: ± 10.0 VDC (A to B)
  • Transmit Interval: 0.5 to 64 ms (selectable)
  • Word Update: 1 ms to 10 sec, (selectable)
  • Burst Mode: 01 to 99 burst outputs at a selectable rate
  • Display Format: Prestored engineering units, full or data field hex and binary, user, and ASCII
  • Maximum Words: 128 per channel
  • Transmit Word Gap: 2, 3, 4, 5, 6, 8, 12 bits (selectable)
  • Dynamic Transmit: Repeat pattern of ramps and flat segments. Levels programmable between ± full scale and segment times of 0 to 999.999 sec
  • Additional Transmit Options: Recorded data, prestored tables

ARINC 429 Breakpoint Operation

  • Label Sequence: A, B, A or B, A then B, A immediate B
  • Data Conditions: EQ, NEQ, OR, GT, LT, /GT/, /LT/
  • Event Count: 1 to 99 before break
  • History: Up to 24,576 words in a programmable window about the breakpoint; optional time stamp
  • Trigger Pulse: 5V, 20 µs

ARINC 429 Record Operation

  • Channels: Up to 16 labels from any combination of receive ports
  • Sample Interval: 1 ms to 10 sec (selectable)
  • Record Capacity: 120 Kbytes (e.g., 8.5 hours of single label at 1/sec)
  • Playback Options: Graphic plots, data lists, DAC download, RS-232C download

ARINC 429 Bite Operation

  • BITE Formats: Compatible with distributed and centralized BITE concept used on 747-400, 737-300, MD-11, A320, A330, and A340 aircraft
  • Menu Display: Standard 14-line x 24-character format, with selectable menu choices
  • Maintenance Words: Displays 350/351 label maintenance bits. Bit status along with prestored text presented
  • Recording Feature: Save up to 240 BITE screens for later viewing or downloading

Size: 6.3 in H, 9.75 in W, 2 in D

Weight: 24 lbs

Power Requirements: 18-36 VDC 20 Watts; 105-250 VAC, 47-400 Hz 20 Watts, rechargeable internal battery, typically providing 6-8 hours of operation.